RODI issues

Joined
Jul 30, 2018
Messages
749
Likes
389
Points
18
Location
VICTORVILLE CA
#1
I was given a rodi unit baracuda 100gpd the restrictor was messed up so I replaced the back flush with built in restrictor(BRS). Membrane(New) is seated correctly all seals are good. I have a cp8800 booster pump which I also got at brs pressure still does not climb above 40 psi. Tds out of the membrane is 99 to 105. My city of Victorville does not use cloromines per their report. I installed a valve before the first di to build pressure, My filters start with sediment, 5 micron carbon, 1 micron carbon, membrane, cation, anion, then mixed bed. My anion will get depled in about 60g. I feel like the membrane is not rejecting TDS.
20230522_131431.jpg
 
Last edited:
Joined
Jun 2, 2015
Messages
193
Likes
16
Points
18
Location
Oceanside
#3
Look up diagrams online make sure everything is in the correct order. Also did you increase the booster pump pressure with the set screw on the top of the pump?


Sent from my iPad using Tapatalk
 
Joined
Jul 30, 2018
Messages
749
Likes
389
Points
18
Location
VICTORVILLE CA
#5
Look up diagrams online make sure everything is in the correct order. Also did you increase the booster pump pressure with the set screw on the top of the pump?


Sent from my iPad using Tapatalk
Booster can only be turned down. I hooked up the booster to my friends rodi and it built pressure good. Not sure why mine is more free flowing.
 
Joined
Jun 2, 2015
Messages
193
Likes
16
Points
18
Location
Oceanside
#6
I saw you put the flush restrictor from brs, make sure there also isn’t a capillary flow restrictor installed inside the waste line coming out of the membrane


Sent from my iPad using Tapatalk
 

drexel

New member
Joined
Nov 1, 2016
Messages
1,461
Likes
1,288
Points
8
Location
SFV
#9
The membrane may not be seated properly, which would cause a few issues. It sounds like the lines might be mixed up somewhere too, do you have a diagram to double check the lines?
 
Joined
May 5, 2008
Messages
393
Likes
26
Points
18
#10
Is your booster pump adjustable? I would work on getting to ~60+psi and then troubleshoot other issues if any
 
Joined
Jul 30, 2018
Messages
749
Likes
389
Points
18
Location
VICTORVILLE CA
#12
I took the tds meter off the di and tested the tds coming out of the faucet and its reading 105. Coming out of the membrane it's 103 what the heck is this thing missing.
 