I was given a rodi unit baracuda 100gpd the restrictor was messed up so I replaced the back flush with built in restrictor(BRS). Membrane(New) is seated correctly all seals are good. I have a cp8800 booster pump which I also got at brs pressure still does not climb above 40 psi. Tds out of the membrane is 99 to 105. My city of Victorville does not use cloromines per their report. I installed a valve before the first di to build pressure, My filters start with sediment, 5 micron carbon, 1 micron carbon, membrane, cation, anion, then mixed bed. My anion will get depled in about 60g. I feel like the membrane is not rejecting TDS.