Chiller repair

JPLreefer

New member
Joined
May 16, 2013
Messages
153
Likes
1
Points
0
Location
La Mirada, CA
#21
Ok next question, how do you have it plumbed? Inline with your return or out of sump back into sump?

Sent from my SM-N900P using Tapatalk
 
Joined
Mar 6, 2015
Messages
146
Likes
1
Points
18
Location
Valley Village
#22
I have mine plumbed inline. My return runs up and splits off to a manifold that has 4 union ball valves. I just run it off of one those. I have it go through my UV sterilizer first, then into the chiller, and then back into my return pump chamber. I don't have it return into my skimmer chamber, which is chamber number one for me, because my temp probe is there.
 
Joined
Mar 6, 2015
Messages
146
Likes
1
Points
18
Location
Valley Village
#25
The UV sterilizer is right behind the skimmer cup. I connect the chiller to the outflow side of the sterilizer, then run the return hose from the chiller behind the pipes and into my return chamber.
 

JPLreefer

New member
Joined
May 16, 2013
Messages
153
Likes
1
Points
0
Location
La Mirada, CA
#26
So is the best way to hook up a chiller, to put a pump in the return pump side and go to the chiller, then have it return back into the first chamber?

Sent from my SM-N900P using Tapatalk
 
Joined
Oct 8, 2011
Messages
5,411
Likes
33
Points
48
Location
Tustin
#27
I plumbed a manifold into my return line for chiller and reactors..

Sent from my Nexus 6 using Tapatalk
 
Joined
Mar 6, 2015
Messages
146
Likes
1
Points
18
Location
Valley Village
#29
It all depends on where you have your temp probe at. Where is your temp probe located? I have mine in the first chamber of my sump, so i don't want the chiller to return the water to that section because then the chiller will turn off when only that chamber gets down to my desired water temp. I have the chiller return into my return section so that it can go directly into the tank, cool down the tank, and then drain into the first section of my sump which has my temp probe that regulates my chiller.
 

JPLreefer

New member
Joined
May 16, 2013
Messages
153
Likes
1
Points
0
Location
La Mirada, CA
#30
Ok so I haven't had the opportunity to run it with vinegar yet. I got sent out to NY for the week. Luis, I have 2 temp probes, one in the sump, and one in the display. By what you said, I should base my chiller function by my sump temp probe and not my display
 