I looked at the problem this morning, and it was definitely the siphon on the ATO line. So I drill a small hole on the fill line in the reservoir. It got to an inch of the top of the sump. While I was draining my sump, I also noticed that my reservoir was completely filled, which shouldn't have happened since I programmed the APEX to refill only once per week (on Sunday) for 8 hours.
So I looked at the programming for the refill of ATO reservoir, and it is wrong because the conditions weren't "nested", it just reads the code from top to bottom. I have to get used to how APEX programming works.
So I googled and changed the code a bit, and it's trial and error at this point.
Original code (wrong):
Code:
Fallback OFF
Set OFF
If DoW -MTWTFS Then OFF
If Time 00:00 to 08:00 Then ON
Min Time 005:00 Then OFF
New code (hopefully correct):
Code:
Fallback OFF
Set OFF
If DoW S------ Then ON
When On > 480:00 Then OFF
Min Time 005:00 Then OFF